DB-1701
J&W DB-1701 GC Columns from Agilent Technologies
Agilent J&W DB-1701 is low/mid-polarity, bonded, cross-linked and solvent-rinsable. It is ideal for the analysis of pesticides, herbicides, trimethylsilyl (TMS) derivatives of sugars and related- substances, and aroclors. The column is also available with DuraGuard (the GC column with a built-in guard column) and is tested to some of the strictest industry GC standards.
Agilent J&W DB-1701P is specifically designed and processed for the analysis of organochlorine pesticides. The low- to mid-polarity columns are ECD tested to ensure minimal pesticide breakdown and low ECD bleed, and operate effectively within temperature limits of -20 to 260/300 °C. These precision-engineered columns are tested to Agilent's stringent industry QC standards. As DB-1701P columns are bonded and cross-linked they are also solvent rinsable and deliver high levels of accuracy and stability in a variety of applications.
All pictures shown are for illustration purpose only. Actual product may vary.
- Buy
- Features
-
DB-1701 GC Columns
Agilent J&W DB-1701 is solvent-rinsable and low-midpolarity for enhanced analysis of pesticides, herbicides, TMS sugars, and aroclors.- (14%-Cyanopropyl-phenyl)-methylpolysiloxane
- Solvent rinsable with low/mid polarity
- Bonded and cross-linked
- Exact replacement of HP-1301 and HP-1701
- Available with DuraGuard (the GC column with a built-in guard column)
Similar Phases: SPB-1701, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-1701
DB-1701P GC Columns
Agilent J&W DB-1701P is bonded, cross-linked and solvent rinsable, delivering excellent performance in the analysis of organochlorine pesticides.- Low/mid-polarity
- Exact replacement of HP-PAS1701
- Specifically designed and processed for the analysis of organochlorine pesticides
- ECD tested to ensure minimal pesticide breakdown and low ECD bleed
- Bonded and cross-linked
- Solvent rinsable
Similar Phases: SPB-1701, Rtx-1701, BP-10, CB-1701, OV-1701, 007-1701, ZB-1701P
- Specifications
-
DB-1701 Temperature Specifications
ID (mm) 0.10 mm 0.18 – 0.32 mm 0.53 mm Length (m) 20 m 10 – 60 m 15 – 60 m Film (µm) 0.10 – 0.40 µm 0.15 – 1.00 µm 0.25 – 1.50 µm Temperature Limits (°C) –20 – 280/300 °C –20 – 280/300 °C –20 – 260/280 °C DB-1701P Temperature Specifications
ID (mm) 0.25 – 0.32 mm 0.53 mm Length (m) 25 – 30 m 30 m Film (µm) 0.25 µm 1.00 µm Temperature Limits (°C) -20 - 280/300 °C -20 - 260/280 °C - Literature
-
-
Agilent GC Column Brochure
Full range of Agilent Technologies GC Columns and Applications
-